Specifications

Electrical

Operation

Class 2 – DC Luminaire*
Current Reg.: Passive
Driver Compatibility: Universal

*Requires a remote power supply

Input Voltage

24V

Max Load

100W per UL8750 class 2 requirements.

Driver Requirements

24 VDC – Constant Voltage
PWM-type Output (if dimmable)
Certified for remote operation
Recommended LM-24V.100W

Wiring

– Ceiling/Wall –
Wiring option « B12« , UL Listed, NEC/CEC compliant CMP plenum-rated white cable, 12.0″ (0.3 m) – 20 AWG – Red(+)/Black(-), polarized with asymmetrically aligned crimp butt splices connectors for permanent connection.
– Millwork –
All wiring options, UL Certified, AWM Style 2464 black cable, 20 AWG – Red(+)/Black(-), polarized.

Application & Warranty

Application

Powerful and flexible, LIFELINE product family simply connect and pivot anywhere along the product and can be repositioned unrestrictedly.

Warranty

Three (3) years on parts.
See terms and conditions.

Standards compliance

UL Listed, CE, RoHS compliant and FCC compliant.

Physical

Construction

Aluminium body.
Copper conductor.
Thin steel strip.

Finish

ABK – Anodized Black
ACL – Anodized Clear
MW – Matte White

Mounting

T – Installation with double side tape
S – Installation with screws

Dimensions

X = 0.38” (9.6 mm)
Y = 0.50” (12.7 mm)
W = 0.80” (20.0 mm)
Z = Configurable length available from 2.7” (68.6 mm) up to 100.0” (2540.0 mm) in increments of 0.1″ (2.6 mm).

Downloads

  • AutoCAD Drawings
  • Installation Sheet
  • Wiring Diagrams
  • Photometric files (IES)

Ordering Code

LLS

24V